Europe

Česko

España

Suomi

France

Magyarország

Italia

Nederland

Polska

Россия

Sverige

Asia and Pacific

日本

Türkiye

中国

India

North America

United States

Search

Selected filters

Product

AC

AC (with display)

AC actuator controls are your perfect solution if the application requires self-adapting control functions, data logging, a configurable interface or if valve and actuator are to be integrated into a Plant Asset Management System due to advanced diagnostic functions.

AC actuator controls are equipped with a parallel interface for free configuration and/or interfaces to fieldbus systems as used within process automation.

The diagnostic functions comprise a time-stamped event report, torque characteristics logging, continuous recording of temperatures and vibration within the actuator and, furthermore, counting the number of starts and motor running times.

Further to the basic functions, AC actuator controls offer a number of options to meet special demands. These include torque bypass to unseat valves if tightly seated or functions for extending operating times to avoid water hammer within pipelines.

With the development of the AC 01.2, particular emphasis was laid on user-friendliness and the ease of integration of actuators into the DCS. The large graphic display is used to perform menu-controlled programming of the actuator controls, optionally using AUMA CDT via wireless Bluetooth connection. For fieldbus connections, AC programming can be performed from the control room.

To the product

Product

AC-SIL/ACExC-SIL

AC (with display)

AUMA offers sophisticated control for premium safety requirements with AC 01.2-SIL or ACExC 01.2-SIL actuators controls. SA .2 and SQ .2 actuators combined with these actuator controls can be deployed in safety-related system systems up to SIL 3. AC 01.2 actuator controls in SIL version are equipped with an additional SIL module designed for the execution of safety functions. In case of an emergency at the plant and when requesting a safety function, the standard logic of AC is bypassed and the safety function is performed via the safe SIL module. Consequently, the safety function always overrules standard operation. SA .2 and SQ .2 actuators equipped with these actuator controls have been certified by TÜV Nord. They are suitable for the following safety functions:

  • Safe OPENING/CLOSING (ESD) up to SIL 2 (single-channel system) or SIL 3 (redundant system) according to IEC 61508 Ed. 2
  • Safe STOP up to SIL 2 (single-channel system) according to IEC 61508 Ed. 2
  • Safe end position feedback signal up to SIL 2 according to IEC 61508 Ed. 2 or up to PL c according to ISO 13849 (not integral part of the certificate. A separate declaration of incorporation is available.)

To the product

Product

ACExC

AC (with display)

Explosion-proof devices must be used in plants where potentially explosive atmospheres are likely to occur. These devices are designed so that they will not act as an ignition source. They neither generate ignition sparks, nor hot surface temperatures. Certification is performed in close collaboration with national and international certification bodies. For multi-turn actuators SAEx/SAREx 07.2 – SAEx/SAREx 16.2 and part-turn actuators SQEx/SQREx 05.2 – SQEx/SQREx 14.2, AUMATIC ACExC 01.2 actuator controls with integral local controls are available.

To the product

Product

AM

AM (without display)

AM actuator controls with their straightforward design are the perfect choice when using parallel signal transmission while a relatively low number of feedback signals is required. Few parameters need to be defined via sliding switches during commissioning, e.g. type of seating in end positions. Control is made via operation commands OPEN, STOP, CLOSE. Reaching an end position and collective fault signals are reported back to the DCS as feedback signals. These signals are visually displayed at the local controls via the indication lights. As an option, the valve position can be transmitted as 0/4 – 20 mA signal to the DCS.

To the product

Product

AMExC

AM (without display)

Explosion-proof devices must be used in plants where potentially explosive atmospheres are likely to occur. These devices are designed so that they will not act as an ignition source. They neither generate ignition sparks, nor hot surface temperatures. Certification is performed in close collaboration with national and international certification bodies. For multi-turn actuators SAEx/SAREx 07.2 – SAEx/SAREx 16.2 and part-turn actuators SQEx/SQREx 05.2 – SQEx/SQREx 14.2, AUMA MATIC AMExC 01.1 actuator controls with integral local controls are available.

To the product

Product

Protection cover and lock kits

Accessories

The lockable protection covers and lock kits prevent unauthorised operation of actuator controls or handwheels.

  • Protection cover for AC 01.2
  • Protection cover for AM
  • Protection cover for AMExC
  • Lock kit for manual and motor drive
  • Lock for manual drive
  • Padlocks

To the product

Product

Sunshade

Accessories

The sunshade is a valuable aid to protect actuator controls against environmental impacts.

To the product

Product

Parking frame

Accessories

Parking frame (PAF) for safe storage of unplugged electrical connections, providing protection against direct touch of open contacts.

The variants equipped with pin carriers allow preserving the available fieldbus connection when disconnecting the actuator controls.

To the product

Product

SA

Multi-turn actuators

SA multi-turn actuators are rated for open-close duty and positioning duty (classes A and B) / (short-time duty S2 - 15 min). Special sizing for longer running times is available for the S2 - 30 min duty.

The actuators can be combined with different actuator controls: From simple OPEN-CLOSE actuator controls to the micro-controlled version with logging of operating data or fieldbus interface.

To the product

Product

SAREx

Multi-turn actuators

Explosion-proof devices must be used in plants where potentially explosive atmospheres are likely to occur. These devices are designed so that they will not act as an ignition source. They neither generate ignition sparks, nor hot surface temperatures.

Certification is performed in close collaboration with national and international certification bodies.

To the product

4991-5000 of 5152 Results

Selected filters

Filter options
Reset all filters