A1: AUMATIC AC 01.2 with position feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
A2: AUMATIC AC 01.2 with positioner and postition feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
A2N: AUMATIC AC 01.2 with positioner and position/torque feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
A3: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B1/B2
A3: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B3
A3N: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B1/B2
A3N: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B3
A4DP: AUMATIC AC 01.2 with positioner and position feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class A1 - A3
A4MB: AUMATIC AC 01.2 with positioner and position feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class A1 - A3
A4N: AUMATIC AC 01.2 with process controller and position/torque feedback signal, thyristors CLOSE, OPEN, STOP, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B1/B2
A4NDP: AUMATIC AC 01.2 with positioner and position/torque feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class A1 - A3
A4NMB: AUMATIC AC 01.2 with positioner and position/torque feedback signal, reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class A1 - A3
A5DP: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B1/B2
A5DP: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B3
A5MB: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B1/B2
A5MB: AUMATIC AC 01.2 with positioner and position feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B3
A5NDP: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B1/B2
A5NDP: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B3
A5NMB: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B1/B2
A5NMB: AUMATIC AC 01.2 with positioner and position/torque feedback signal, thyristors OPEN, STOP, CLOSE, EMERGENCY, MODE, BUS/External (24 V DC), AUMA power class B3
AC1: AUMATIC AC 01.1, position feedback signal 0/4 - 20 mA (potentiometer in actuator), contactors, OPEN - STOP - CLOSE - EMERGENCY (24 V DC), 6 programmable signal relays
AC1N:AUMATIC AC 01.1, position feedback /torque feedback signal 0/4 - 20mA (MWG in actuator), contactors, OPEN - STOP - CLOSE - EMERGENCY (24 V DC), 6 programmable signal relays
AC1NW:AUMATIC AC 01.1, position feedback/torque feedback signal 0/4 - 20 mA (MWG in actuator), wall bracketcontactors, OPEN - STOP - CLOSE - EMERGENCY (24 V DC), 6 programmable signal relays
AC2: AUMATIC AC 01.1, positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator), contactors, OPEN - STOP - CLOSE - EMERGENCY - MODE (24 V DC), nominal value (0/4 - 20 mA),6 programmable signal relays
AC2N:AUMATIC AC 01.1, positioner and position feedback/torque feedback signal 0/4 - 20 mA (MWG in actuator), contactors, OPEN - STOP - CLOSE - EMERGENCY - MODE (24 V DC), nominal value (0/4 - 20 mA), 6 programmable signal relays
AC2NFF: AUMATIC AC 01.1 Foundation Fieldbus, position feedback/ torque signal (potentiometer in actuator), contactors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)
AC2NMB:AUMATIC AC 01.1 MODBUS-RTU, position feedback/torque feedback signal (MWG in actuator), contactors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)
AC3: AUMATIC AC 01.1, positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator), thyristors, OPEN - STOP - CLOSE - EMERGENCY - MODE (24 V DC), nominal value (0/4 - 20 mA),6 programmable signal relays
AC3FF: AUMATIC AC 01.1 Foundation Fieldbus, position feedback signal (potentiometer in actuator), thyristors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)
AC3N:AUMATIC AC 01.1, positioner and position feedback/torque feedback signal 0/4 - 20 mA (MWG in actuator), thyristors, OPEN - STOP - CLOSE - EMERGENCY - MODE (24 V DC), nominal value (0/4 - 20 mA),6 programmable signal relays
AC3NDP:AUMATIC AC 01.1 PROFIBUS-DP, position feedback/torque feedback signal (MWG in actuator), thyristors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)
AC3NFF: AUMATIC AC 01.1 Foundation Fieldbus, position feedback/ torque signal (potentiometer in actuator), thyristors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)
AC3NMB:AUMATIC AC 01.1 MODBUS-RTU, position feedback/torque feedback signal (MWG in actuator), thyristors, OPEN - STOP - CLOSE, nominal value (0 - 100 %)